Sterility testing is one of the most crucial steps in pharmaceutical product release. False positives, false negatives, equipment failure and human error can cost you time, money and ultimately your product.
The Steritest Equinox transfer pump is a software controlled peristaltic pump used for the safe, uniform transfer of drug samples from various packaging formats through the Steritest sterility testing devices. The Steritest Equinox pump and Steritest devices deliver unmatched sterility testing consistency and reliability.
The Next Generation Intelligent Pump: from a computer, standard operating procedures (SOPs) can be developed and then loaded onto the Steritest Equinox pump. In automated mode, an analyst simply selects the appropriate SOP for the sample to test from the Steritest Equinox control panel. The Steritest Equinox pump will walk the analyst through each step, acting as a training guide, thereby supporting good manufacturing practices. The various steps in the procedure, corresponding pump speed and related information are displayed on the control panel, improving repeatability and reliability.
Analysts can select either manual or automated mode. In manual mode, the Steritest Equinox pump will prompt the analyst to enter data at each step of the procedure.
BrunoTomazelli ⎜May 30, 2017 ⎜
Radio detectors for PET and SPECT and solutions for β and γ measurements. Beta and gamma radiodetectors with different detector technologies and shieldings to cover a wide range of radio-HPLC methods.
Radio-flow monitors can be connected to any existing HPLC system including preparative LC system, either using digital data transfer or an analog-to-digital converter.
BrunoTomazelli ⎜May 30, 2017 ⎜
The portable contamination monitor is using 2 scintillator materials. For detection of alpha-radiation ZnS is used. For detection of beta and gamma radiation a plastic scintillator foil is used.
The large area detector window is permeable for low energy alpha radiation like U-238 beta radiation like C-14 The thin window can be replaced easily by the user and measurements can be continued without much delay.
The light flashes generated by the alpha or beta/gamma radiation can be separated by pulse analysis.
The detected events are counted over time and displayed digitally in c/s, Bq or Bq/cm2. Nuclide specific sensitivity is calculated and alarm values are preprogrammed.
Measurement results can be stored and transferred by RS 232 C.
BrunoTomazelli ⎜May 30, 2017 ⎜
Fullcheck: automatically checks the device functions during power on. Also during operation a complete instrument check can be carried out at a single key stroke. Here also display and keypad are checked besides the electrical characteristics.
Sensoface: checks the electrode and provides information on the electrode condition. The zero, slope, response time and glass impedance of the electrode as well as the calibration interval are evaluated.
Calimatic: automatically recognizes the right buffer. It allows calibration at the stroke of a key, providing ease of use and – above all – safety.
Trueline: delivers a calibrated analog recorder signal, of course electrically isolated. This provides you with a true pH signal, calibrated for the electrode and without disturbing quantizing levels, permitting undistored recording of pH curves.
BrunoTomazelli ⎜May 30, 2017 ⎜
The osmometer determines the osmolality by measuring the freezing point depression of the liquid sample.
The Osmolality describes the concentration of osmotic effective particles in the sample solutions. This is independent from type, composition or electrical charge of the solution, because it refers to the mass of the solution.
The system allows a simple handling with a short measuring time. The system has been adapted to the use of radioactive substances, reducing the irradiation risk.
BrunoTomazelli ⎜May 30, 2017 ⎜
One of the main applications of GC Systems is in SPECT and PET laboratories for residual solvents control.
As the injected samples contain radioactivity, methods were optimized to gain time, reduce sample amount and improve radioprotection.
All units including the column oven, flow controller and sample injection unit are comprehensively optimized at the design stage to achieve highest precision.
BrunoTomazelli ⎜May 30, 2017 ⎜
The system is a FDA licensed endotoxin detection system. It is a rapid point of use test system that provides quantitative test results in less than 15 minutes. The technology utilizes licensed LAL reagents in a disposable cartridge using the PTS for a completely contained, real time endotoxin assay.
The PTS is perfect in a conventional quality control settings.
BrunoTomazelli ⎜May 30, 2017 ⎜
The dose calibrator is designed for the fast and accurate determination of the activity or volume activity of radiopharmaceuticals.
It is PC-based and comes with a control and evaluation software. The system is used in nuclear medicine for diagnostics and therapy, it is calibrated for most common radionuclides, including the RSO nuclides (Y-90, Er-169, Re-186) and the PET nuclides (e.g. F-18, I-124).
The system has a USB connection and the software is taking in account influencing factors for containers (e.g. syringe, eluate bottle, capsule) and contents.
The dose calibrator is a certified medical device class II b.
BrunoTomazelli ⎜May 30, 2017 ⎜
Analytical balance for determination of accurate weight for preparation of precursors for the synthesis of PET compounds.
The analytical balance has a large display for easy reading of the determined weight.
Multiple weight units including a user defined custom unit for use in unique weighing applications.
The pan is made of stainless steel and is easy to clean. Frameless draft screen is available as an option. QuadraStance incorporates for adjusting feet to provide superior footprint stability on any surface.
The balance has a front level indicator for fast check before any use.
The balance can be operated by AC and/or battery. An automatic shut off feature helps to conserve battery life.